SEIDENADER VIALS AND AMPOULES INSPECTION MACHINE, MODEL V90-AVSB/60 – RL
Year of construction: 2007
Semi-automatic spotting machine for detecting cosmetic particles and defects in vials, ampoules, etc. Adjustable high-precision rollers allow high-speed rotation of vials, vials and bottles.
REQUIREMENTS
Electrical
Power supply: 230 V~, 50 Hz, 1 Phase Consumption: 1.0 kW (max.) Electrical cabinet: IP 54Compressed air
Connection: 1/4” Pressure: 6 bar (Working pressure); 4,5 bar (minimal pressure)Consumption
Depends on speed and reject rate 0% / Rejects 0 l/min 100% / Rejects 120 l/minCHARACTERISTICS
Weight: 500 kg ca. Temperature: +10°C / to +40°C Relative Humidity: 5 – 95 % (without condensation) Noise level: 71 dB(A) (DIN 45635) drive belts PUR conveyor belt PUR cover PMMA (acrylic glass) flex. tubes, colour Silicone, PUR O-Ring, black EPDM suction cup Silicone Star grip, knurled screw PA roller castor PAUsed materials
stainless steel Aluminium anodised black plastics POM white plastics POM green plastics LD-PE (s-grün) coatings PTFECompare listings